tissue type plasminogen activator Search Results


91
Assaypro tissue plasminogen activator t pa
Tissue Plasminogen Activator T Pa, supplied by Assaypro, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/10__1042_slash_bsr20171657-420-4-17?v=Assaypro
Average 91 stars, based on 1 article reviews
tissue plasminogen activator t pa - by Bioz Stars, 2026-07
91/100 stars
  Buy from Supplier

90
Innovative Research Inc tissue type plasminogen activator t pa
Tissue Type Plasminogen Activator T Pa, supplied by Innovative Research Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/10__23937_slash_2378___2951_slash_1410272-37-26-20?v=Innovative+Research+Inc
Average 90 stars, based on 1 article reviews
tissue type plasminogen activator t pa - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Boster Bio human plat tpa elisa kit ez set
Human Plat Tpa Elisa Kit Ez Set, supplied by Boster Bio, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/10__1186_slash_s43088___026___00740___3-110-27-33?v=Boster+Bio
Average 90 stars, based on 1 article reviews
human plat tpa elisa kit ez set - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

93
Elabscience Biotechnology human tissue type plasminogen activator elisa kit
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Human Tissue Type Plasminogen Activator Elisa Kit, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pmc11926568-138-1-8?v=Elabscience+Biotechnology
Average 93 stars, based on 1 article reviews
human tissue type plasminogen activator elisa kit - by Bioz Stars, 2026-07
93/100 stars
  Buy from Supplier

93
Aladdin Scientific Corporation tissue sections
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Tissue Sections, supplied by Aladdin Scientific Corporation, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pmc12700179-75-0-10?v=Aladdin+Scientific+Corporation
Average 93 stars, based on 1 article reviews
tissue sections - by Bioz Stars, 2026-07
93/100 stars
  Buy from Supplier

95
Assaypro tpa tissue type plasminogen activator
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Tpa Tissue Type Plasminogen Activator, supplied by Assaypro, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pm23478319-74-8-34?v=Assaypro
Average 95 stars, based on 1 article reviews
tpa tissue type plasminogen activator - by Bioz Stars, 2026-07
95/100 stars
  Buy from Supplier

95
Assaypro p selectin
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
P Selectin, supplied by Assaypro, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pm37175392-146-19-25?v=Assaypro
Average 95 stars, based on 1 article reviews
p selectin - by Bioz Stars, 2026-07
95/100 stars
  Buy from Supplier

94
Assaypro human tpa chromogenic assaysense activity assay kit
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Human Tpa Chromogenic Assaysense Activity Assay Kit, supplied by Assaypro, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pmc08495465-11312-18-25?v=Assaypro
Average 94 stars, based on 1 article reviews
human tpa chromogenic assaysense activity assay kit - by Bioz Stars, 2026-07
94/100 stars
  Buy from Supplier

93
Cusabio tissue type plasminogen activator tpa
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Tissue Type Plasminogen Activator Tpa, supplied by Cusabio, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/10__12659_slash_msm__893544-74-62-67?v=Cusabio
Average 93 stars, based on 1 article reviews
tissue type plasminogen activator tpa - by Bioz Stars, 2026-07
93/100 stars
  Buy from Supplier

91
Innovative Research Inc human tissue type plasminogen activator tpa
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Human Tissue Type Plasminogen Activator Tpa, supplied by Innovative Research Inc, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pm37996063-226-11-23?v=Innovative+Research+Inc
Average 91 stars, based on 1 article reviews
human tissue type plasminogen activator tpa - by Bioz Stars, 2026-07
91/100 stars
  Buy from Supplier

90
Innovative Research Inc rat tpa activity assay kit
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Rat Tpa Activity Assay Kit, supplied by Innovative Research Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pm22155932-104-67-72?v=Innovative+Research+Inc
Average 90 stars, based on 1 article reviews
rat tpa activity assay kit - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Hemochrom Ultra Pure human -thrombin
AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) <t>ELISA</t> for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.
Human Thrombin, supplied by Hemochrom Ultra Pure, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tissue+type+plasminogen+activator/pm15111498-27-2-6?v=Hemochrom+Ultra+Pure
Average 90 stars, based on 1 article reviews
human -thrombin - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

Image Search Results


AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) ELISA for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.

Journal: CNS Neuroscience & Therapeutics

Article Title: Asparagine Endopeptidase Inhibition Attenuates Tissue Plasminogen Activator‐Induced Brain Hemorrhagic Transformation After Ischemic Stroke

doi: 10.1111/cns.70345

Figure Lengend Snippet: AEP KO ameliorates tPA‐associated hemorrhagic transformation in the stroke mouse model. (A, B) Representative images of hematoma in brain slices and quantification of hemoglobin levels. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (C) Recorded brain water content to assess brain edema at 24 h after delayed tPA administration. Data are presented as mean ± SEM and statistical analysis is performed using one‐way ANOVA test followed by Tukey's multiple comparisons test. (D) ELISA for tPA activity detection. Data are presented as mean ± SEM and statistical analyses are performed using Welch test followed by Dunnett T3 multiple comparisons test were applied since the P value of Levene test < 0.05. (E) Representative images of HE staining in the cortical hematoma area (scale bar = 50 μm). (A), (C) n = 6, (D) n = 4 per group. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.

Article Snippet: A human Tissue‐type Plasminogen Activator ELISA kit (E‐EL‐H2106, Elabscience) was used for detection.

Techniques: Transformation Assay, Enzyme-linked Immunosorbent Assay, Activity Assay, Staining

The 7,8‐DHF prodrug R13 confers protection in mice against neurological dysfunction, hemorrhagic transformation, and BBB disruption after cerebral ischemia and tPA treatment. Mice were given R13 (dissolved in 5% DMSO/0.5% methylcellulose) at a dose of 21.8 mg/kg/day, 7 days per week, for 2 weeks by gavage, followed by MCAO/R. Surgery and delayed tPA treatment. (A, B) Representative images of TTC staining and the corresponding proportion of the infarct area. (C, D) Representative images of hematoma in brain slices and quantification of hemoglobin levels. (E, F) Representative images and leakage quantification of Evans Blue staining. (G, H) Longa Scores and Corner Turn tests used for sensorimotor function examination. (I) ELISA for tPA activity detection. (A), (C), (F), (I) n = 4, (G, H) n = 20 per group. Data are presented as mean ± SEM, and statistical analyses are performed using one‐way ANOVA test followed by Tukey's multiple comparisons test when P value of Levene test > 0.05 or Welch test followed by Dunnett T3 multiple comparisons test when the P value of Levene test < 0.05. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.

Journal: CNS Neuroscience & Therapeutics

Article Title: Asparagine Endopeptidase Inhibition Attenuates Tissue Plasminogen Activator‐Induced Brain Hemorrhagic Transformation After Ischemic Stroke

doi: 10.1111/cns.70345

Figure Lengend Snippet: The 7,8‐DHF prodrug R13 confers protection in mice against neurological dysfunction, hemorrhagic transformation, and BBB disruption after cerebral ischemia and tPA treatment. Mice were given R13 (dissolved in 5% DMSO/0.5% methylcellulose) at a dose of 21.8 mg/kg/day, 7 days per week, for 2 weeks by gavage, followed by MCAO/R. Surgery and delayed tPA treatment. (A, B) Representative images of TTC staining and the corresponding proportion of the infarct area. (C, D) Representative images of hematoma in brain slices and quantification of hemoglobin levels. (E, F) Representative images and leakage quantification of Evans Blue staining. (G, H) Longa Scores and Corner Turn tests used for sensorimotor function examination. (I) ELISA for tPA activity detection. (A), (C), (F), (I) n = 4, (G, H) n = 20 per group. Data are presented as mean ± SEM, and statistical analyses are performed using one‐way ANOVA test followed by Tukey's multiple comparisons test when P value of Levene test > 0.05 or Welch test followed by Dunnett T3 multiple comparisons test when the P value of Levene test < 0.05. Normality and variance are assessed via Shapiro‐Wilk test and Levene's test, respectively. * P < 0.05, ** P < 0.01.

Article Snippet: A human Tissue‐type Plasminogen Activator ELISA kit (E‐EL‐H2106, Elabscience) was used for detection.

Techniques: Transformation Assay, Disruption, Staining, Enzyme-linked Immunosorbent Assay, Activity Assay